Mechanical use
[Mechanical use]
Use mechanical arm to work with the injector molding machine.
[Mechanical unuse]
Run the injector molding machine without mechanical arm.
① Press [+]/[-] in the [mechanical use] status.
② Then it jumps to the screen below.
③ -1
Press [ESC] to cancel the operation to the initial screen.
④ -2
When the ascend limit is ON and the safety door is open,press [ENTER]
to enter into the mode [mechanical unuse].
While the ascend limit is OFF and the safety door is OFF,it will not jump to any
other screen nor remind you of any alarms after you press[ENTER].
⑤ When it jumps to the [machine unuse] screen,I/O relative to the injector molding
machine is forced ON.
⑥ Press [F1] to use the machine again and it jumps to system setting 1 screen.