Rockwell Automation Publication MOTION-RM002H-EN-P-February 2018  165 
Affects Math Status Flags 
No 
Major/Minor Faults 
None specific to this instruction. See Common Attributes for operand-related 
faults.   
Execution 
Ladder Diagram 
Condition/State  Action Taken 
Prescan  The .EN, .DN, .ER, and .IP bits are cleared to false. 
Rung-condition-in is false  The .EN bit is cleared to false if either the .DN or .ER bit is true. 
Rung-condition-in is true    The .EN bit is set to true and the instruction executes.   
Postscan  N/A 
Structured Text 
Condition/State  Action Taken 
Prescan  See Prescan in the Ladder Diagram table.   
Normal execution  See Rung-condition-in is false, followed by rung is true in the Ladder Diagram 
table. 
Postscan  See Postscan in the Ladder Diagram table.   
Extended Error Codes 
Extended Error Codes provide additional instruction specific information for the 
Error Codes that are generic to many instructions. Extended Error codes for the 
Parameter Out of Range (13) error code lists a number that refers to the number 
of the operand as they are listed in the faceplate from top to bottom with the first 
operand being counted as zero. Therefore for the MCSV instruction, an extended 
error code of 2 would refer to the Master Value operand’s value. You would then 
have to check your value with the accepted range of values for the instruction. See 
Motion Error Codes (.ERR) for Motion Instructions. 
MCSV Changes to Status Bits 
None