Motion Group Instructions 
 
  Rockwell Automation Publication MOTION-RM002H-EN-P-February 2018  231 
MOTION_INSTRUCTION Structure 
Mnemonic  Description 
.EN (Enable) Bit 31  It is set when the rung makes a false-to-true transition and remains set until the servo 
message transaction is completed and the rung goes false. 
.DN (Done) Bit 29  It is set when the group of axes have been successfully set to Shutdown state. 
.ER (Error) Bit 28  It is set to indicate that the instruction detected an error, such as if you specified an 
unconfigured group. 
Description 
The MGSP instruction synchronously latches all command and actual position 
values of all axes in the specified group at the time of execution. The MGSP 
instruction takes only one parameter; simply select or enter the desired axis to 
strobe. 
If the targeted group does not appear in the list of available groups, the group has 
not been configured for operation. Use the Tag Editor to create and configure a 
new groups. 
The MGSP instruction may be used at any time to capture a complete set of 
command and actual position information for all axes in the specified group. This 
operation is often required as a precursor to computations involving position 
values of different axes within the group. 
To successfully execute a MGSP instruction, the targeted group must be 
configured. 
Important: 
The MGSP instruction execution completes in a single scan, setting the 
Done .DN bit immediately. 
This is a transitional instruction: 
•  In relay ladder, toggle Rung-condition-in from false to true each time the 
instruction should execute. 
•  In structured text, condition the instruction so that it only executes on a 
transition. 
Affects Math Status Flags 
No 
Major/Minor Faults 
None specific to this instruction. See Common Attributes for operand-related 
faults.