Motion Configuration Instructions 
 
  Rockwell Automation Publication MOTION-RM002H-EN-P-February 2018  307 
Available Languages 
Ladder Diagram 
 
Function Block 
This instruction is not available in function block. 
Structured Text 
MAAT(Axis,MotionControl); 
Operands 
There are data conversion rules for mixed data types within an instruction. See 
Data Conversions. 
Ladder Diagram and Structured Text 
Operand  Type  Format  Description 
Axis  AXIS_SERV0 
AXIS_SERV0_DRIVE 
Tag  Name of the axis to perform 
operation on 
Motion Control  MOTION_INSTRUCTION  Tag  Structure used to access instruction 
status parameters. 
See Structured Text Syntax for more information on the syntax of expressions 
within structured text.   
MOTION_INSTRUCTION Structure 
Mnemonic  Description 
.EN (Enable) Bit 31  The enable bit indicates when the instruction is enabled. It remains set until 
servo messaging completes and the Rung-condition-in goes false. 
.DN (Done) Bit 29  The done bit indicates when the instruction completes an apply axis-tuning 
process. 
.ER (Error) Bit 28  The error bit indicates when the instruction detects an error, such as if the axis 
is not configured.