139  10  MCPM Dyn Data Invalid Value 
MCPM Dyn Data Orientation Decel 
If the orientation decel is zero or negative or INF or NAN, the 
instruction will report this error. 
Diagnostic Codes and Corrective Actions 
N/A 
Example 
Ladder Diagram 
 
Structured Text 
MCPM (CS1, MCPM1, MyPath1, 1, MyDynamics1, 0, 0); 
See also 
Structured Text Syntax on page 635
 
Index Through Arrays on page 663 
Motion Error Codes (.ERR) on page 557 
Motion Coordinated Linear Move (MCLM) on page 437 