Motion State Instructions 
 
  Rockwell Automation Publication MOTION-RM002H-EN-P-February 2018  57 
Operands 
Ladder Diagram and Structured Text 
Operand  Type  Format  Description 
Axis  AXIS_SERVO  Tag  Motion Axis of data type AXIS_SERVO 
only. 
Motion Control  MOTION_INSTRUCTION  Tag  Structure used to access instruction 
status parameters. 
Drive Output  SINT 
INT 
DINT 
REAL 
Immediate 
or Tag 
Voltage to output in % of servo Output 
Limit or in Volts. 
Drive Units  Boolean  Immediate  How do you want to interpret the drive 
output? 
0 = Volts 
1 = Percent 
See Structured Text Syntax for more information on the syntax of expressions 
within structured text.   
Enter your selection for the operands that require you to select from available 
options: 
This Operand  Has These Options Which You... 
Enter As Text  Or Enter As a Number 
DriveUnits  Volts 
Percent 
0 
1 
MOTION_INSTRUCTION Structure 
Mnemonic  Description 
.EN (Enable) Bit 31  It is set when the rung makes a false-to-true transition and remains set until the servo 
message transaction is completed and the rung goes false. 
.DN (Done) Bit 29  It is set when the axis’ drive enable bit is activated and the specified analog output is 
successfully applied. 
.ER (Done) Bit 28  It is set to indicate that the instruction detected an error, such as if you entered a Drive Output 
value that was too large.