Gas Category
Country
Gas
Category
Supply Pressure (mbar)
Manifold Pressure (mbar)
nominal
minimum
maximum
II
2H3B/P
BG, CY, CZ,
DK, EE, FI,
HR, LT, NO,
SE, SI SK
G20 2H 20 17 25 8.0
G30/31 3B/P (30) 30 (28-30) 25 35 *
II
2H3B/P
HU G20 2H 25 18 33 8.0
G30/31 3B/P 50 42.5 57.5 27.5
II
2H3B/P
AT, CH G20 2H 20 17 25 8.0
G30/31 3B/P 50 42.5 57.5 27.5
II
2H3+
CH, ES, GB,
GR, IE, IT, TR
G20 2H 20 17 25 8.0
G30 3+ (28-30/37)
Butane
30 (28-30) 25 35 *
G31 3+ (28-30/37)
Propane
37 25 45 *
II
2E3B/P
PL G20 2E 20 17 25 8.0
G30 3B/P 30 (28-30) 25 35 *
II
2E3B/P
LU G20 2E 20 17 25 8.0
G30/31 3B/P 50 42.5 57.5 27.5
II
2E3B/P
II
2E(LL)3B/P
DE G20 2E(LL)/2E 20 17 25 8.0
G25 2E(LL) 20 17 25 12.0
G30/31 3B/P 50 42.5 57.5 27.5
II
2E(r)3+
FR G20 2E(r) 20 17 25 8.0
G25 2E(r) 20 17 25 12.0
G30 3+ (30/37) Bu-
tane
30 (28-30) 25 35 *
G31 3+ (30/37)
Propane
37 25 45 *
II
2L3B/P
NL G25 2L 25 20 30 12.0
G30 3B/P 30 (28-30) 25 35 *