Connection to a power source, by a licensed electrician, and quantity of receptacles used for a given circuit
must be in compliance with all national and local electrical codes. Connect a maximum of 13 receptacles
(12 in Canada, and fewer in certain U.S. locales) to one circuit. Consult applicable national and local
electrical codes.
Disconnect electrical connections between panels prior to removal of a mechanical connection. Ensure that
the power supply is disconnected prior to disconnecting any electrical components.
When electrical components are interconnected from one panel to another, the panels must be mechanically
connected per the appropriate panel-to-panel installation instructions.
Failure to observe these warnings could result in a fire or electrical shock.
WARNING
Illustration 1: General Configuration and Component Identification
Illustration 2: Electrical Wiring Diagrams
GREEN/BARE
GREEN/BARE
GRN/BARE
Component Identification: Color of terminal ends and
receptacle backs are BLACK.
Component Identification: Color of terminal ends and
receptacle backs are RUST.
Power harness 871224
Power harness
8712XX
Notes: All electrical components
are UL Listed to UL1286
and UL183.
By pulling on terminal
housing at end of cable
assemblies, Power and
Pass-Thru harnesses can
be stretched up to 3
1
/
2
"
.
4 hot / 2 neutral / 2 ground systems:
color of terminal ends are black.
3 hot / 3 neutral / 2 ground systems:
color of terminal ends are rust.
Pass-Thru harness 8711XX
Pass-Thru cable 8710XX
•
Connect to previously installed cable
•
Stretch, as required, to proper position
•
Snap onto mounting bracket
8 Wire Electrical Installation