This setting is the amount of time the processor takes to scan the signal to decide if the gesture on the pad is a
dampen stroke. The higher the number, the more accurate the dampening stroke will be. The higher the number
also adds delay. Experiment with the right setting for you.
Global Auxiliary Shortcut #45
malletKAT Express
Auxiliary Editing Screens require pressing the Edit Footswitch and Sustain 1 pedal at the same time (See Section
4.1.1(https://alternatemode.com/online-docs/malletkat/#malletkat-express-accessing-editing-functions)
)
DAMPEN RATIO
Parameters = 0-255
This screen sets a ratio between the dampen signal and the normal signal. When you apply pressure to the pad, a
rise is detected in the signal. Changing this parameter helps the malletKAT to evaluate the difference between a
stroke and a pressured dampen stroke.
Global Auxiliary Shortcut #15
malletKAT Express
Auxiliary Editing Screens require pressing the Edit Footswitch and Sustain 1 pedal at the same time (See Section
4.1.1(https://alternatemode.com/online-docs/malletkat/#malletkat-express-accessing-editing-functions)
)
DAMPEN THRESHOLD
Parameters = 00-255
This setting is used to adjust the dampening characteristics of the malletKAT when played in DAMPEN Mode. The
Dampen Threshold is a measure of how much pressure is required to get damping to occur. Raising this value
decreases the likelihood of dampening, lowering it makes dampening easier.
Global Auxiliary Shortcut #04
malletKAT Express
Auxiliary Editing Screens require pressing the Edit Footswitch and Sustain 1 pedal at the same time (See Section
4.1.1(https://alternatemode.com/online-docs/malletkat/#malletkat-express-accessing-editing-functions)
)
DATA DUMP RECEIVE
Parameters = Enabled, Disabled
You make choose to Enable or Disable the receiving of Data Dumps back into your malletKAT Pro. The default
setting is Enable.