58 • MN-35949 • Rev 04 • 06/16 • Combitherm® CT PROformance™ Series • Technical Service Manual
Error Codes
Error
Code
Error Call Out in Display Description of Error Possible Cause(s)
E90 Lower Gas Combustion Blower
Not at Speed
Speed is too slow. — Power supply cable is not connected to blower motor.
— Speed control cable is not connected to blower motor.
— Blower motor is blocked, rotation is impeded, or motor is
faulty.
— Faulty control board.
E91 Upper Gas Blower Not at
Speed
Speed is to slow. — Power supply cable is not connected to blower motor
— Speed control cable is not connected to blower motor
— Blower motor is blocked, rotation is impeded, or motor is
faulty
— Faulty control board
E92 Communication Error
CB does not properly respond
Twelve (12) instances of no-
response from the relay board
(CB) to the display board (IB).
— Check CAN cable connections.
— CAN cable defective.
— Relay board, low voltage, connector defective.
— Display board connector defective.
E93 Interface Board (IB) and
Control Board (CB) are in
diff erent states
The IB is in a diff erent running
state than the CB for more than
20 seconds.
— Check CAN cable connections.
— CAN cable defective.
— Relay board, low voltage, connector defective.
— Display board connector defective.
E94 Communication Error,
TO Interface Board
No signal transfer for more than
5 seconds between the Interface
Board (IB) and the Control Board
(CB).
— Check CAN cable connections.
— CAN cable defective.
— Relay board, low voltage, connector defective.
— Display board connector defective.
E100 One or more maintenance
reminder has timed out.
When any maintenance
reminder has expired without
action having been taken by the
operator.
— Enter maintenance reminder screen and address the item
that has timed out and reset
E101 Ventless Hood Fault - No
Pressure
If the power switch or pressure
switch is not closed.
Check power switch is on.
Check vent motor is turning in the proper direction.
— Pressure switch is miss wired or defective.
— Filter(s) require cleaning or replacement
E102 Ventless Hood Fault — Filters
Not Present
If the air filter switches are not
closed.
Check filters are installed and properly seated.
Check filter switches are not damaged, defective or
dislodged.
E103 Option Board Doesn’t Send
Switch Setting
OB not communicating its switch
settings to the CB.
— Check CAN cable connection between OB and CB.
— Ensure CB dip switch is set to see an OB.
— Incompatible OB and CB so ware (update so ware).
— OB defective.
— CB defective.
E104 Option Board Not
Communicating
Option board is not
communicating with CB.
— Check option board CAN connection at CB and OB.
— Defective OB.
— Defective CB.
continued on next page

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alto-Shaam COMBITHERM CTC Series and is the answer not in the manual?

Alto-Shaam COMBITHERM CTC Series Specifications

General IconGeneral
BrandAlto-Shaam
ModelCOMBITHERM CTC Series
CategoryOven
LanguageEnglish

Related product manuals