MN-35949 • Rev 04 • 06/16 • Combitherm® CT PROformance™ Series • Technical Service Manual • 59
Error Codes
Error
Code
Error Call Out in Display Description of Error Possible Cause(s)
E105 No or Low Water Pressure Water pressure switch not
activated.
— Water supply not connected.
— Water supply is shut off .
— Water supply to unit blocked or obstructed
— Faulty or miswired pressure switch
E106 Boiler Drain Pump Fault Hall eff ect or rotational sensor is
not sending a signal to the relay
board
— Drain pump motor not running or defective.
— Hall eff ect sensor broken or incorrectly wired.
— Motor improperly wired.
E108 Cooling Fan Failure If the temperature on the control
board (relay board) is greater
than 140ºF (60ºC) and less than
176ºF (80ºC). (See error code
E02)
— Cooling fan damaged.
Cooling fan blocked or blades have been kept from rotating.
— Incoming air temperature exceeds 100°F (38°C).
— Air inlet has become blocked.
E109 High Limit Switch
NOTE: Any oven experiencing
this error should be
investigated by an authorized
Alto-Shaam service provider.
The High Limit Switch input to
the CB (N7) is “open”
— Unit has experienced an over heat condition.
— Convection element contactors stuck closed.
— Failed Y1 solenoid.
Obstruction between Y1 solenoid and injection pipe.
— Improperly connected drain.
— Condensate pan clean out not closed.
Improperly wired high limit switch at the switch or at the
CB.
— Defective high limit switch.
E200 The SD card has been detected
to be larger than 2GB in size.
The SD card inserted is larger
than 2GB in size.
SD card is larger than 2GB in size. Contact service to order
replacement SD card.
E210 VFD Under Voltage VFD has detected an under-
voltage situation.
— Possible VFD failure.
E211 VFD Over Voltage VFD has detected an over-voltage
situation.
— Possible VFD failure.
E212 VFD Overheating VFD has detected an overheat
situation.
— Unit has experienced an over heat condition.
— Defective high limit switch.
— Defective cooling fans.
— Possible VFD failure.
E213 Motor Over Current Motor over current detected. — Blocked fan wheel.
— Possible VFD failure.
E214 VFD Current Peak VFD current peak detected. — Possible VFD failure.
E215 VFD EEPROM Error VFD EEPROM error detected. — Possible VFD failure.
E216 VFD Over Current VFD over current detected. — Possible VFD failure.
E217 VFD Short Circuit VFD Short Circuit detected. — Possible VFD failure.
E218 VFD Voltage Error VFD voltage does not correspond
to jumper settings.
— VFD voltage jumper is not correct.
— Possible VFD failure.
continued on next page

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alto-Shaam COMBITHERM CTC Series and is the answer not in the manual?

Alto-Shaam COMBITHERM CTC Series Specifications

General IconGeneral
BrandAlto-Shaam
ModelCOMBITHERM CTC Series
CategoryOven
LanguageEnglish

Related product manuals