APPENDIX D: COMMUNICATION CODES
UNIFLOW
®
4 PULSED HEAT CONTROL
D-8 990-908
121 AUX_START
122 AUX_PREHEAT
123 AUX_REFLOW
124 SOLDER_COOL_VALVE
3 Bytes Total
PROFILE “DR” Read Profile # 2 Bytes
“DS” Set ProfileNum (Profile number to be modified: 01 - 63) 2 Bytes
, 1 Byte
PreheatTemp (Preheat temperature: 060 - 300) 3 Bytes
, 1 Byte
ReflowTemp (Reflow temperature: 060 - 600) 3 Bytes
, 1 Byte
Cool1Temp (Cool1 temperature: 025 - 300) 3 Bytes
, 1 Byte
PreheatTime (Preheat time: 000 – 999) 3 Bytes
, 1 Byte
Rise2Time (Rise2 time: 00 – 99) 2 Bytes
, 1 Byte
ReflowTime (Reflow time: 000 – 999) 3 Bytes
, 1 Byte
BaseTemp (Base temperature: 025 – 300) 3 Bytes
1 Byte
PostheatTemp (Postheat temperature: 025 - 600) 3 Bytes
, 1 Byte
Cool2Temp (Cool2 temperature: 025 - 300) 3 Bytes
, 1 Byte
IdleTemp (Idle temperature: 025 - 100) 3 Bytes
, 1 Byte
BaseTime (Preheat time: 000 – 999) 3 Bytes
, 1 Byte
PostheatTime (Postheat time: 000 – 999) 3 Bytes
, 1 Byte
Rise1Time (Rise1 time: 00 – 99) 2 Bytes
, 1 Byte
GRAPH Time Span (000-999) 3 Bytes
1 Byte
Head Up Delay (000-999) 3 Bytes
1 Byte
Schedule Reference (0000000000-ZZZZZZZZZZ) 10 Bytes
1 Byte
CoarseRate (Coarse heating rate: 0 – 3) 1 Byte
0 = Very Slow
1 = Slow
2 = Medium
3 = Fast
, 1 Byte
FineRate (00 – 99) 2 Bytes
, 1 Byte
Preheat Reflow Control (0=TIME, 1=TEMP) 1 Byte
, 1 Byte
Preheat Delta Temperature (00 – 99) 2 Bytes