APPENDIX D: COMMUNICATION CODES
UNIFLOW
®
4 PULSED HEAT CONTROL
990-908 D-9
, 1 Byte
Reflow Delta Temperature (00 – 99) 2 Bytes
, 1 Byte
PID Control (100 – 269) 3 Byte
, 1 Byte
Solder Cool Valve Delay (00 – 99 2 Bytes
91 Bytes Total
PROFILE “PR” Read Profile # 2 Bytes
“PS” Set ProfileNum (Profile number to be modified: 01 - 63) 2 Bytes
1 Byte
Enable Peak and Average Limits (1 = yes, 0 = no) 1 Byte
1 Byte
Preheat Peak Upper Temperature Limit (000-999) 3 Bytes
1 Byte
Preheat Peak Lower Temperature Limit (000-999) 3 Bytes
1 Byte
Reflow Peak Upper Temperature Limit (000-999) 3 Bytes
1 Byte
Reflow Peak Lower Temperature Limit (000-999) 3 Bytes
1 Byte
Preheat Peak Delay (000-999) 3 Bytes
1 Byte
Preheat Avg Delay (000-999) 3 Bytes
1 Byte
Rise1 Envelope Delay (00-99) 2 Bytes
1 Byte
Rise2 Envelope Delay (00-99) 2 Bytes
1 Byte
Preheat Average Upper Temperature Limit (0-999) 3 Bytes
1 Byte
Preheat Average Lower Temperature Limit (0-999) 3 Bytes
1 Byte
Reflow Average Upper Temperature Limit (0-999) 3 Bytes
1 Byte
Reflow Average Lower Temperature Limit (0-999) 3 Bytes
1 Byte
Enable Preheat Envelope Limits (1 = yes, 0 = no) 1 Bytes
1 Byte
Enable Reflow Envelope Limits (1 = yes, 0 = no) 1 Bytes
1 Byte
Preheat Upper Temperature Limit (000-999) 3 Bytes
1 Byte
Preheat Lower Temperature Limit (000-999) 3 Bytes
1 Byte