17. Switch on the spreading disc drive.
18. Open the left shutter.
19. When the collection bucket is full,
close the left shutter.
20. Switch off the spreading disc drive.
21. Weigh the collected quantity.
CMS-I-00006174
22. Enter the weight of the collected quantity.
23. Select "Continue".
The new calibration factor will be displayed.
24. Save the calibration factor
or
To optimise the calibration factor,
repeat the calibration.
CMS-I-00006175
10 | Determining the calibration factor at a standstill
MG7387-EN-II | B.1 | 12.01.2022