Troubleshooting
16
Error code Errors Cause Solution
F45001 Left limiter sensor failed The signal from the path
measurement system of the
linear drive for the left limiter
is less than 0.5 V.
Eliminate damage or
interruptions on the cable
to the linear drive.
Replace defective linear
drive (EA460).
F45002 Right limiter sensor failed The signal from the path
measurement system of the
linear drive for the right limiter
is less than 0.5 V.
Eliminate damage or
interruptions on the cable
to the linear drive.
Replace defective linear
drive (EA460).
F45003 Setpoint value cannot be
maintained
The desired spread rate
cannot be spread with the
working width and speed.
see page 46
F45004 Left limiter is not responding Although the linear drive on
the left limiter is switched on,
the voltage value of the path
measurement system in this
drive does not change.
see page 46
F45005 Right limiter is not responding Although the linear drive on
the right limiter is switched on,
the voltage value of the path
measurement system in this
drive does not change.
see page 46
F45008 Left shutter not completely
closed
The left shutter was not
completely closed.
Close the left shutter.
F45009 Right shutter not completely
closed
The right shutter was not
completely closed.
Close the right shutter.
F45010 Left shutter is not responding The measured value of the
sensor on the left shutter
does not change, although
the setting motor of the
shutter has been switched on.
see page 47
CMS-T-00008989-B.1
MG7387-EN-II | B.1 | 12.01.2022
43