16.1 F45003: Setpoint value cannot be maintained
The desired spread rate cannot be spread with the working width and speed.
1. Reduce speed.
2. Reduce spread rate.
3. Reduce the working width
16.2 F45004: Left limiter is not responding
Although the linear drive on the left limiter is switched on, the voltage value of the path
measurement system in this drive does not change.
1. Remove blockage in the limiter.
2. Eliminate damage or interruptions on the cable to
the linear drive.
3. Replace defective linear drive (EA460).
16.3 F45005: Right limiter is not responding
Although the linear drive on the right limiter is switched on, the voltage value of the path
measurement system in this drive does not change.
1. Remove blockage in the limiter.
2. Eliminate damage or interruptions on the cable to
the linear drive.
3. Replace defective linear drive (EA460).
CMS-T-00008994-A.1
CMS-T-00008999-A.1
CMS-T-00008998-A.1
MG7387-EN-II | B.1 | 12.01.2022
46