16.4 F45010: Left shutter is not responding
The measured value of the sensor on the left shutter does not change, although the
setting motor of the shutter has been switched on.
1. Eliminate any damage or interruptions on the
cable connection to the setting motor.
2. Hook the shutter back into the setting motor after
the calibration.
3. Replace the defective setting motor (EA461).
16.5 F45012: Right shutter is not responding
The measured value of the sensor on the right shutter does not change although the
setting motor of the shutter has been switched on.
1. Eliminate any damage or interruptions on the
cable connection to the setting motor.
2. Hook the shutter back into the setting motor after
the calibration.
3. Replace the defective setting motor (EA461).
16.6 F45027: Overcurrent at output: EEL 092/EEL 093 spread fan illumination
The power consumption of the spread fan illumination is too high
1. Check light and wiring harness
2. Replace defective light (NA297)
3. Replace defective wiring harness
16.7 F45032: Overcurrent at output: EEL 090 hopper lighting
The power consumption of the hopper lighting is too high
1. Check light and wiring harness
2. Replace defective light
3. Replace defective wiring harness
CMS-T-00008996-A.1
CMS-T-00008995-A.1
CMS-T-00009016-A.1
CMS-T-00009015-A.1
16 | Troubleshooting
MG7387-EN-II | B.1 | 12.01.2022
47

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Amazone AmaSpread 2 and is the answer not in the manual?

Amazone AmaSpread 2 Specifications

General IconGeneral
BrandAmazone
ModelAmaSpread 2
CategoryFarm Equipment
LanguageEnglish

Related product manuals