Error code Errors Cause Solution
F45032 Overcurrent at output: EEL
090 hopper lighting
The power consumption of
the hopper lighting is too high
see page 47
F45049 Fill level alarm limit undercut The residual quantity in the
hopper set by the user has
been reached.
Refill the hopper
F45058 The selected source for the
forward speed is not available
The AmaSpread 2 terminal is
not receiving a speed signal.
Select an existing source.
Activate the speed signal
in the terminal settings.
F45062 Fill level alarm limit undercut The residual quantity in the
hopper set by the user has
been reached.
Refill the hopper.
F45063 Setpoint value cannot be
maintained
The desired spread rate
cannot be spread with the
working width and speed.
see page 48
F45064 Left fill level too low The left low level sensor is no
longer attenuated.
Refill fertiliser.
Deactivate the low level
alarm in the User
settings.
F45065 Right fill level too low Right fill level too low Refill fertiliser.
Deactivate the low level
alarm in the User
settings.
F45066 Weighing active, hopper soon
empty. Stop and interrupt
calibration run
During a calibration run, the
hopper content drops below
300 kg.
Come to a stop and
interrupt the calibration
run.
F45067 Calibration run can only be
started and stopped at a
standstill
The button for starting or
stopping the calibration run
was pressed while driving.
Come to a stop and start
or interrupt the calibration
run.
F45068 Hopper fill level too low for
calibration run
The hopper fill level is too low
for a calibration run.
Refill fertiliser
F45069 Recurring error when
determining the calibration
factor
During the automatic
calibration, the newly
calculated calibration factor
was below 0.5 twice.
see page 48