Error code Errors Cause Solution
F45012 Right shutter is not
responding
The measured value of the
sensor on the right shutter
does not change although the
setting motor of the shutter
has been switched on.
see page 47
F45015 Left shutter angle sensor
failed
The signal from the angle
sensor of the left shutter is
less than 4 mA.
Eliminate damage or
interruptions on the cable
to the angular motor.
Replace the defective
angle sensor (NH195).
F45016 Right shutter angle sensor
failed
The signal from the angle
sensor of the right shutter is
less than 4 mA.
Eliminate damage or
interruptions on the cable
to the angular motor.
Replace the defective
angle sensor (NH195).
F45019 Electric lifting cylinder of left
shutter failed
The power consumption of
the setting motor on the left
shutter is above 6 A.
Remove blockage in the
shutter.
Replace the defective
angle sensor (NH195).
F45020 Electric lifting cylinder of right
shutter failed
The power consumption of
the setting motor on the right
shutter is above 6 A.
Remove blockage in the
shutter.
Replace the defective
angle sensor (NH195).
F45022 Spreading disc speed cannot
be maintained
The spreading disc speed
deviates from the set nominal
speed by more than 50 rpm.
Adjust the speed on the
PTO shaft until the correct
spreading disc speed is
achieved.
F45026 Tilt sensor failed The tilt sensor delivers less
than 4 mA on one of its two
signals.
Eliminate damage or
interruptions on the cable
to the tilt sensor.
Replace defective tilt
sensor (NH186).
F45027 Overcurrent at output: EEL
092/EEL 093 spread fan
illumination
The power consumption of
the spread fan illumination is
too high
see page 47
F45028 Left weigh cell failed The signal of the left weigh
cell is less than 4 mA.
Eliminate damage or
breaks on the cable to the
weigh cell.
Replace defective weigh
cell.
F45029 Right weigh cell failed The signal of the left weigh
cell is less than 4 mA.
Eliminate damage or
breaks on the cable to the
weigh cell.
Replace defective weigh
cell.
16 | Troubleshooting
MG7387-EN-II | B.1 | 12.01.2022
44