EasyManua.ls Logo

AMX DAS-M-0404 - RS-232 Commands; Messages; RS-232 Controller Command Messages

AMX DAS-M-0404
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RS-232 Commands / Messages
67
Mi Series Audio Controllers
RS-232 Commands / Messages
RS-232 Controller Command Messages
RS-232 Controller Command Messages
MVER Get Firmware Version Firmware Status Version
- or -
ERR
MCGF Get Configuration Configuration Status
- or -
ERR
FNIC Get Number of IIC devices Num IIC Devices Status
- or -
ERR
FGICx Get IIC Device Status, where:
x’ is the IIC device index, valid values range from 1 to the
number of available IIC devices as reported in the ‘Num IIC
Devices Status’
IIC Device Status
- or -
ERR
AMX AMX Beacon Poll AMX Beacon Response
- or -
ERR
MGBD Get Baud Rate Baud Rate Status
- or -
ERR
BDHI Set Baud Rate to 9600 Baud Rate Status
- or -
ERR
BDLO Set Baud Rate to 4800 Baud Rate Status
- or -
ERR
MSVLr,v Set Volume, where:
•‘r’ is the desired room, (1-64)
•‘v’ is the desired volume level, valid values are:
101: Mute
0....70: 0....-70 dB
Volume Status
- or -
ERR
MGVLr Get Volume, where:
r’ is the desired room, (1-64)
Volume Status
- or -
ERR
MSBSr,b Set Bass, where:
•‘r’ is the desired room, (1-64)
•‘b’ is the desired bass level, valid values are:
0: level
1....10: -10....-1 dB
11....20: 1....10 dB
Bass Status
- or -
ERR
MGBSr Get Bass, where:
r’ is the desired room, (1-64)
Bass Status
- or -
ERR

Table of Contents