MVER Get Firmware Version Firmware Status Version
- or -
ERR
MCGF Get Configuration Configuration Status
- or -
ERR
FNIC Get Number of IIC devices Num IIC Devices Status
- or -
ERR
FGICx Get IIC Device Status, where:
x’ is the IIC device index, valid values range from 1 to the
number of available IIC devices as reported in the ‘Num IIC
Devices Status’
IIC Device Status
- or -
ERR
AMX AMX Beacon Poll AMX Beacon Response
- or -
ERR
MGBD Get Baud Rate Baud Rate Status
- or -
ERR
BDHI Set Baud Rate to 9600 Baud Rate Status
- or -
ERR
BDLO Set Baud Rate to 4800 Baud Rate Status
- or -
ERR
MSVLr,v Set Volume, where:
•‘r’ is the desired room, (1-64)
•‘v’ is the desired volume level, valid values are:
101: Mute
0....70: 0....-70 dB
Volume Status
- or -
ERR
MGVLr Get Volume, where:
r’ is the desired room, (1-64)
Volume Status
- or -
ERR
MSBSr,b Set Bass, where:
•‘r’ is the desired room, (1-64)
•‘b’ is the desired bass level, valid values are:
0: level
1....10: -10....-1 dB
11....20: 1....10 dB
Bass Status
- or -
ERR
MGBSr Get Bass, where:
r’ is the desired room, (1-64)
Bass Status