RS-232 Commands / Messages
73
Mi Series Audio Controllers
Tango Audio Controller Status Messages
RS-232 Controller Command Messages (Cont.)
MV++r Increment Volume, where:
‘rr’ is the desired room, (1-64)
Volume Status
- or -
ERR
MV--r Decrement Volume, where:
‘r’ is the desired room, (1-64)
Volume Status
- or -
ERR
SGSTx,y Get General Sirius Status, where:
•‘x’ = Sirius number (1-2)
•‘y’ = status selection (0-7)
Sirius Radio Status
- or -
ERR
SGID Get Sirius Radio ID, where
‘x’ = Sirius number (1-2)
Sirius Radio ID Status
- or -
ERR
SGCIx Get Sirius Channel Information, where
‘x’ = Sirius number (1-2)
Sirius Channel Status
- or -
ERR
SGCTx Get Sirius Category Information, where
‘x’ = Sirius number (1-2)
Sirius Category Status
- or -
ERR
Controller Status Messages
ERR Error
ACK Acknowledge Status
PON Power On Status
Note: Not used
POFF Power Off Status
Note: Not used
MVERx Firmware Version Status, where ‘x’ is the current firmware version (4 digits)
MCFr,s,z,c Configuration Status, where:
•‘r’ is the number of rooms connected, valid values are 2-64
•‘s’ is the number of sources connected, valid values are 4,6,8
•‘z’ is the number of groups available, valid values are 1 or ‘r’/2
•‘c’ is the clock available status, where:
0: no clock installed
1: clock module is present
ERR Error
ACK Acknowledge Status
PON Power On Status
Note: Not used
POFF Power Off Status
Note: Not used
MVERx Firmware Version Status, where ‘x’ is the current firmware version (4 digits)
MCFr,s,z,c Configuration Status, where:
•‘r’ is the number of rooms connected, valid values are 2-64
•‘s’ is the number of sources connected, valid values are 4,6,8
•‘z’ is the number of groups available, valid values are 1 or ‘r’/2
•‘c’ is the clock available status, where:
0: no clock installed
1: clock module is present