RS-232 Commands / Messages
72
Mi Series Audio Controllers
RS-232 Controller Command Messages (Cont.)
MGPSs,n Get the preset, where:
•‘s’ is the desired source, (1-8)
•‘n’ is the desired preset, (1-10)
Preset Status
- or -
ERR
MSTPs Get the source type, where:
s’ is the desired source, valid values are 1-8
Source Type Status
- or -
ERR
MSSDs,d Send Source Direct Data, where:
•‘s’ is the desired source, valid values are 1-8
•‘d’ is the direct tuning string, the meaning of the data depends on
the source type:
0: undefined – direct data is not processed
1: AM/FM Tuner – station frequency; if FM then there will be a ‘.’
in the frequency string
2: CD Changer – disk and track, in the format ‘ddd.ttt’ where
‘ddd’ is the disk and ‘ttt’ is the track
3: DVD Player – disk and track, in the format ‘ddd.ttt’ where ‘ddd’
is the disk and ‘ttt’ is the track
4: Satellite Receiver – ‘ssss’ where ‘ssss’ is the station number
5: Audio Server - disk and track, in the format ‘ddd.ttt’ where
‘ddd’ is the album and ‘ttt’ is the title
6: Other – direct data sent as received
7: Custom XM – ‘sss’ for channel
8: Internal Sirius Tuner – ‘ccc.ssss’ where ‘ccc’ is Category and
‘ssss’ is channel number
20: Internal AM/FM Tuner– station frequency; if FM then there
will be a ‘.’ in the frequency string
Source Status
- or -
Sirius Radio Channel
Number Status
(Sirius Type Only)
- or -
ERR
MGSSs Get Source Status, where:
s’ is the desired source, (1-8)
Source Status
- or -
ERR
CSSTh,m,s Set the Clock Time, where:
•‘h’ is the desired hour, (0-23)
•‘m’ is the desired minute, (0-59)
•‘s’ is the desired second, (0-59)
Clock Status
- or -
ERR
CGST Get the Clock Time Clock Status
- or -
ERR
CSALr,s,v,h,m Set the Clock Alarm, where:
•‘
r’ is the desired room, (1-64)
•‘s’ is the desired source, (1-8)
•‘v’ is the desired volume, valid values are:
101: Mute
0...55: 0...-55 dB
•‘h’ is the desired hour, (0-23)
•‘m’ is the desired minute, (0-59)
Alarm Status
- or -
ERR
CCALr Clear the Clock Alarm, where ‘ris the desired room. Valid values
are:
0: clear the alarm for all rooms
1-64: clear the alarm for the specified room
Alarm Status
- or -
ACK
- or -
ERR
CGALr Get the Clock Alarm, where
r’ is the desired room (1-64)
Alarm Status
- or -
ERR