RS-232 Commands / Messages
71
Mi Series Audio Controllers
RS-232 Controller Command Messages (Cont.)
MARGgg,r Add Room to Group, where:
•‘g’ is any room already in the group, (1-64)
• ‘r’ is the room, (1-64)
Room Grouping Status
- or -
ERR
MRRGr Remove Room from Group, where:
r’ is the room to remove, (1-64)
Note: The Room Grouping will be removed if less than 2 rooms
are associated with the given source.
Room Grouping Status
- or -
ERR
MDRG Dissolve all Room Groupings ACK
- or -
ERR
MGRGr Get Room Grouping, where:
r’ is any room in the grouping, (1-64)
Room Grouping Status
- or -
ERR
MIGVr,i Increment the Volume for a Room Grouping, where:
‘r’ is any room in the grouping, (1-64)
‘i’ is the increment value or 0 for system default
ACK
- or -
ERR
MDGVr,i Decrement the Volume for a Room Grouping, where:
‘r’ is any room in the grouping
‘i’ is the decrement value or 0 for system default
ACK
- or -
ERR
MSGVr,v Set the Volume for a Room Grouping, where:
•’r’ is any room in the grouping
•‘v’ is the desired volume level, valid values are:
101: Mute
0...55: 0...-55 dB
ACK
- or -
ERR
MGRSs Get the Rooms currently listening to a source, where:
s’ is the desired source, (1-8)
Source Grouping Status
- or -
ERR
MSFVr,s,f Set the favorite, where:
•‘r’ is the desired room, (1-64)
•‘s’ is the desired source, (1-8)
•‘f’ is the direct tuning string; it can be from 0 to 7 characters long
and is translated as specified in the ‘Send Source Direct Data’
command: Zero length data will clear the favorite.
Favorite Status
- or -
ERR
MGFVr,s Get the favorite, where:
‘r’ is the desired room, (1-64)
‘s’ is the desired source, valid values are 1-8
Favorite Status
- or -
ERR
MSLOr Lock out the keypad in a room, where:
r’ is the room to lock out, (1-64)
Lock Out Status
- or -
ERR
MCLOr Clear the keypad lock out in a room, where:
r’ is the room to clear the lock out in, (1-64)
Lock Out Status
- or -
ERR
MGLO Get the keypad lock out status for the system. Lock Out Status
- or -
ERR
MSPSs,n,p Set the preset, where:
•‘s’ is the desired source, (1-8)
•‘n’ is the desired preset, (1-10)
•‘p’ is the direct tuning string; it can be from 0 to 7 characters long
and is translated as specified in the ‘Send Source Direct Data’
command: Zero length data will clear the preset
Preset Status
- or -
ERR