EasyManua.ls Logo

Applent Instruments AT682 User Manual

Default Icon
51 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
AT682/683 Megohmmeter
Users Manual
@
®
Instruments, Inc.
Address: Lanlin Dangnan Industrial Park,
Changzhou, Jiangsu, China (PRC)
Post Code: 213014
Telephone (Sales):
0086-0519-88805550 / 89966117/89966227
Fax0086-0519-89966550
Sales Email: sales@applent.com
Tech Email: tech@applent.com
http://www.applent.com
©2005-2011 Applent Instruments, Inc.
The material in this manual is for informational purposes only and is subject to change, without notice. Applent assumes no
responsibility for any error or for consequential damages that may result from the misinterpretation of any procedures in this
publication.
This document contains proprietary information which is protected by copyright.
All rights are reserved.
No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of the
Applent Instruments Inc.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Applent Instruments AT682 and is the answer not in the manual?

Applent Instruments AT682 Specifications

General IconGeneral
BrandApplent Instruments
ModelAT682
CategoryMeasuring Instruments
LanguageEnglish

Summary

Safety Summary

Megohmmeter Safety

1 Unpacking and Preparation

3 Getting Started

4 Comparator

5 Handler Interface

6 Remote Control

7. SCPI Command Reference

7.1 Terminator

Defines the end-of-line terminator character used for SCPI commands (NL, LF, or ASCII '\n').

7.2 Notation Conventions and Definitions

Explains the conventions for symbols, brackets, and commands used in SCPI command descriptions.

7.3 Command Structure

Describes the tree structure of SCPI commands, including common commands and subsystem hierarchy.

7.4 Header and Parameters

Details the format of SCPI command headers and parameters, including character and numeric data types.

7.5 Command Reference

Provides a comprehensive reference for all SCPI commands, organized by functional subsystem.

7.6 Function Subsystem

Covers SCPI commands for setting the measurement parameter (resistance, current) and range.

7.7 VOLTage Subsystem

Details SCPI commands for setting the test voltage applied to the device under test.

7.8 CORRection Subsystem

Explains the SCPI command for performing the OPEN correction function.

7.9 COMParator Subsystem

Covers SCPI commands for setting comparator record number, limit values, and beep.

7.10 STATe Subsystem

Describes SCPI commands for setting the instrument's operating state to CHARG or DISCH.

7.11 TIMEr Subsystem

Details SCPI commands for setting the charge timer and sample timer values.

7.12 APERture Subsystem

Explains SCPI commands for setting the analog-to-digital converter (ADC) convert time.

7.13 SYSTem Subsystem

Covers SCPI commands for controlling system settings, such as keypad lock.

7.14 TRIGger Subsystem

Details SCPI commands for enabling measurements and setting trigger modes (internal, hold, external).

7.15 FETCH Subsystem

Describes the SCPI command to retrieve measurement data initiated by a trigger.

7.16 ERRor Subsystem

Explains the SCPI command to retrieve the last error information from the instrument.

7.17 *IDN? Common Command

Details the SCPI command to query the instrument's model, version, and identification.

A Specifications