24
◯
X Motor overloaded (fan)!
The electric fan is being strained
too long at its limits.
Switch off the implement
and check if there are
objects blocking the fan or
preventing it from rotating
properly.
Check whether the
calibration cover is installed,
and if all of the seeding
hoses are connected.
◯
X Motor overloaded
(spreading plate)!
The spreading plate is not
able to rotate.
The motor is being strained
too long at its limits.
Switch off the implement
and check if there are
foreign objects or similar
that prevent the spreading
disc from rotating properly.
◯
X Motor not connected
(seeding shaft)!
The cables are not or not
properly connected.
Check the cables and plugs.
◯
X Motor not connected
(fan)!
The cables are not or not
properly connected.
Check the cables and plugs.
When using a hydraulic fan:
see chapter 8.2.
◯
X Motor not connected
(spreading plate)!
The cables are not or not
properly connected.
Check the cables and plugs.
◯
X Motor not connected
(pump)!
The pump is not or not properly
connected. The pump's safety
switch is being triggered by
overpressure in the system.
Check the cabling.
Open the valves all the way.
Reduce pressure in the
system: larger nozzles,
more outlets.
Check for blockages and
eliminate them if necessary.
Hydraulic:
The hydraulic fan is not
producing an air current.
The return pressure in the
tank line of the hydraulic fan
motor is too high.
Switch on the hydraulic fan
and wait until the LED lights
up. Then switch on the
seeding shaft.
Check the fastening and the
cables for the fan speed
sensor.
Replace the return line filter.
Do not use a reduction for
the tank line (e.g. BG 3
coupling).
Use a larger tank line.
Electric fan PLUS:
There is no fan connected
and "Electric PLUS" is selected
as the fan motor.
Overload (E2 or E1 on the
motor module).
Check the cables and plugs
for damage.
◯
X No motor speed
(seeding shaft)!
The motor is connected and not
overloaded, but still does not
rotate.
Check the clamp
connections on the
spreader.
Contact customer service.