4.4.5 FAN MONITORING
Here, the type of fan monitoring must be set for a hydraulic PS.
Fan monitoring:
Using the plus/minus buttons, select PRESSURE, SPEED or NO and confirm
with the OK button.
4.4.6 CALIBRATION BUTTON EQUIPPED
Here, you can set whether a calibration button is installed on your PS (available as an accessory).
13. Calibration button
equipped:
Use the plus/minus buttons to select YES or NO and confirm with the OK
button.
The implement is
being switched
off!
After successfully entering this data, the control box switches itself off
automatically so that the entries are saved.
Depending on the selected settings, all of the points might not be requested. However, you can also
change the points as described in chapter 8 Programming 5.2 (customer service).
4.5 MAIN DISPLAY
Switch-on message: Is shown during the switch-on procedure and shows
the type and device version.
This information is very helpful in the case of service and is even essential
for malfunctions to be able to perform diagnosis!
PS, MDC, MDG or MDP operating mode
SS % 25.0
km/h 10.0
SS %: set speed for the seeding shaft (in %)
Must be set using the plus/minus buttons on the control module or
automatically when performing the calibration test.
km/h: forward speed [km/h] defined in menu item I "Calibration test".
MDD or UDW operating mode
SS % 25
km/h 10
kg/ha 20.0
Speed 2000
SS %: set speed for the seeding shaft (in %)
Must be set using the plus/minus buttons on the control module or
automatically when performing the calibration test.
km/h: forward speed [km/h] defined in menu item I "Calibration test".
kg/ha: current spread rate (is only displayed if a valid calibration test was
performed)
LF operating mode
M % 30
km/h 10.0
l/ha 200.0
M %: set motor revolutions (in %). Must be set using the plus/minus buttons
on the control box.
km/h: forward speed [km/h]
l/ha: current spread rate (only in conjunction with speed sensors)
Speed
Speed: the currently set spreading plate speed is changed on the second
menu page, which can be reached by pressing the "up arrow" button (▲),
using the plus/minus buttons.