8.15 MACHINE TYPE
15. Implement type
query when switching
on?
Here, you can set whether the control box should request the used
implement type (PS, MDP, MDG/MDC, MDS, UWD, LF) every time the
control box is switched on.
Use the plus/minus buttons to select YES or NO.
TIP!
If you are using the same controller to operate several different types, you therefore do not need
to enter the Programming menu every time to change the type.
8.16 RESTORING THE FACTORY SETTINGS
Restore the
factory settings?
Here, you can restore the factory settings.
Press the OK button.
Using the plus/minus buttons, select YES and then press the OK button
again.
The set language, the total hours and the total areas are kept in the
process.
9 ACCESSORIES
The following accessories can be ordered for Control Box 5.2:
9.1 7-PIN SIGNAL CABLE
With the 7-pin signal cable, a connection from the tractor to the control
box can be established. In this case, the control module receives 3
signals from the tractor (DIN 9684 standard). The forward speed
[km/h] and the linkage signal (working position) will then be
transmitted from the tractor to the control box. It is shown on the
control box. The seed quantity is now automatically regulated by
regulating the speed of the seeding shaft. As a result, the desired
seed quantity per hectare is always maintained, even if the driven
speed deviates slightly from the defined speed.
The control box takes care of all procedures for the operator, such as
the controlling during the working process. Thanks to the lifting unit
signal, no manual operation on the control box is required when
turning. On some tractors, the lifting unit signal is inverted. If the
seeding shaft rotates as soon as the linkage is lifted out, then proceed
as described under section 8.6.
Order number: 00410-2-155
Cable length: 1.5 m
Connection: 12-pin plug on the control box
Settings: see chapter 8.6
Figure 5
NOTE!
The signal socket is not completely assigned by all tractor manufacturers, even if it is installed
in the cab.