Arkel ArLine User Manual V1.24
The green pictogram LED is activated when the voice communication is started with the rescue service.
The stages of alarming via the Arkel ArLine-S-TP alarm unit are as follows:
Press and hold the yellow alarm button on the unit for 3 seconds. Alarm filtering is not applied to the Arkel ArLine-S-
TP units.
Alarm information is transmitted to the recovery service via ARKEL Cloud and optionally via SMS. The yellow
pictogram LED output is activated.
The ALARM LED on the Arkel ArLine-M unit is activated.
The alarm call is started. A beep will be heard until communication with the rescue service is established.
The green pictogram LED is activated when the voice communication is started with the rescue service
The alarm stages with the programmable input "ALB - Alarm button" on the Arkel ArLine-M unit are as follows:
The external alarm connected to the Arkel ArLine-M unit is pressed for 3 seconds. Alarm filtering is not applied to the
Arkel ArLine-M unit.
This method will communicate with the Arkel ArLine-S-COP unit. Therefore, the next steps are the same as the alarm
stages in the Arkel ArLine-S-COP unit.
One of the following methods can be used to terminate the alarm:
Press and hold the button on the Arkel ArLine-M device for 3 seconds.
By activating an input to which an "EOA - Alarm termination" function is assigned on the Arkel ArLine-M device.
Alarm termination tool on the ARKEL Cloud menu.
When an alarm is triggered from an alarm unit, the yellow pictogram LEDs of the other units are activated with the alarm unit
as well. When the speech is started with the rescue service, only the green pictogram LED on the unit that performs the call is
activated.
Communication can only be terminated by the rescue service.
After the communication is terminated, pressing the alarm button again for 3 seconds will repeat the call.
Rescue service can establish voice communication again with the alarm unit if it is desired.