TD 92582GB
2009-12-15/ Ver. C
User Manual
Ascom d41 DECT Handset
44
LED Error Indications
See also chapter LED Indications during Easy Replacement on page 50.
LED is flashing red, quick flash, (100 ms on, 800 ms off)
1) If a third handset, that is another handset than the "old" (the replaced handset) and
"new" (the replacement heandset) handset, is inserted into the charger during Easy
Replacement, this error indication appears. Change to the correct handset.
2) The charger has found that Easy Replacement does not work. Change back to the
"new" handset.
LED is flashing red, long flash (800 ms on, 100 ms off)
Error during Easy Replacement. Both telephones need to be sent for service.
Could not encrypt
connection
The parameter "Encryption
Required" is enabled in the
handset in combination with;
1) Unencrypted base station(s);
and/or,
2) Unsupported base station(s).
1) Disable the "Encryption
Required" parameter in
handset; and/or,
2) Enable the encryption in the
base station(s); and/or,
Note: If Ascom’s base
station(s) is used, the software
version must be 3.1.x or
greater.
3) Use supported base
station(s). Ask your supplier.