Chapter 4 Digital Output Settings (DIGITAL OUTPUT)
72
*1 About the PW_SAVE setting
When PW_SAVE is set, the VG876 and VG-879 execute the following processing.
<PW_SAVE=ON>
Writes “0x02” to DPCD 0x00600 Bits1:0 (SET_POWER) of the connected sync device and sets Main Link and AUXCH to
the power down state.
<PW_SAVE=OFF>
Wakes up Main Link and AUXCH and writes “0x01” to DPCD 0x00600 Bits1:0 (SET_POWER) of the connected sync
device. At this time, Link Training is not executed. Press “LT” to execute Link Training.
*2 About the AUD_MUTE setting
When Audio Mute = ON is set, operation differs between the VM-1876-M1 and VM-1876A-M1.
VM-1876-M1: The output level becomes 0 (MUTE state) in the state when the audio packet has been transmitted.
AudioMute_Flag (VB-ID bit4) is set to 1.
VM-1876A-M1: The audio packet is not transmitted. (Same state as Audio Output = OFF)
AudioMute_Flag (VB-ID bit4) is set to 1.
*3 About the EDIT settings
If a setting item (e.g., Link Rate) in the EDIT menu is changed, the setting is also reflected for output ports other than the
specified output port (analysis port).