3.4.1 Measuring tools
To measure a tool using quick programming, do the following:
1. Ensure that the transducer and tool are connected. To view tool/Pset in the
Result header, open
Conf>Interface>User and set Show Pset to On.
2 Select menu block
Q.prog
3. Select the correct tool and press
ENTER.
1 Direct driven
Used when testing direct driven tools dynamically.
2 Pulse
Used when testing pulse tools dynamically.
3 Wrench
Used when checking installed torque in an already tightened joint.
4 Click wrench
Used when checking the release torque on a click wrench.
4. Select
OK to use default programming.
If
Pulse is selected, type the filter frequency in the dialog box.
If
Wrench is selected, select Peak (DD) or Static installed torque in the dialog box.
For more information about strategies, see section Measuring strategies.
For m
ore information about filter frequency, contact Atlas Copco.
5. Do the tightening operations.
The result is displayed in the
Measurement dialog box after each tightening.
6. Save and print the result.
Evaluate, and if applicable, calibrate the tool. See section Calibrating tools and equipment.
3.4.2 Measuring controlled tools with synchronization
When using Synchronize, the ACTA is configured to measure the torque in the same way as the controller.
After each tightening operation, ACTA reads the tightening values directly from the controller and from
the transducer, and stores them in the ACTA’s memory.
1. Connect ACTA and controller. To view tool/Pset in the
Result header, open Conf>Interface>User and
set
Show Pset to On.
Note! Depending on controller, a gender converter can be needed to connect to
the RS 232 connector on ACTA.