Measurement results ACTA 4000 User Guide
84 (136) 2008-12 9836 4171 01
Torque and Angle over Time graph with
zooming area shown.
6.3 Batch Result window
As explained in Programming ACTA, under menu block Prog, Programming, you have a choice of
activating
Batch on ACTA Quality Control and Advanced Analysis versions.
In practice, this function will cause ACTA to check and provide a statistical status on Torque, Angle (and
Pulses) after a specific number of measurements - your specified batch. This is what your ACTA then
checks.
You have to set limits for the above parameters for this to work. Set your limits in
Statistical setup in Prog menu block