4.6.3 Delete Tool
This lets you delete either the selected tool or all tools from the database. The tools are deleted along with
their tightening.
Make sure you select the tool up for deletion prior to performing delete selected tool.
It is not possible to delete the default tool.
The delete all tools choice will delete all tools and all tightening from the database.
Only an empty default tool will be left. Once a tool is deleted it is not possible to
recover the tool and it’s associated tightening.
4.6.4 Clear all measurements
This function allows you to delete all measurement data for all your tools in the database.
This will not delete but update your historic statistical measurement data under the
Hist menu block.
Any Tool Calibration reports or Deadweight reports in the database will be deleted
by this action!
4.6.5 Backup tool
This function allows you to create a copy of the selected tool, including all the tightening operations and
history data. This function is used when you have noticed that a tool needs to be adjusted, for example,
and you want to save your existing tightening operations for history data.
A confirmation dialog box appears asking
Are you sure? The backup tool is named with its existing name
and the extension
[#].
For example:
BMX123 ------> BMX123[0] (first backup).
BMX123 ------> BMX123[1] (second backup).
It is not possible to measure with a backup tool.
It is not possible to create a new tool from a backup tool.
It is not possible to make a backup of a backup tool.
After a backup, all tightening in the original tool are removed.