ACTA 4000 User Guide Programming ACTA
9836 4171 01 2008-12 67 (136)
If only one parameter is selected, two pairs of statistical parameters can be selected for that parameter in
the Custom measurement display. For example:
Parameter 1 = Torque
Parameter 2 = None
Statistical parameter 1 = X, σ
Statistical parameter 2 = Min., Max.
This setup will display the statistical parameters X, σ, min and max for torque in the Custom measurement
display.
4.8 Analyse (A.lyse)
This function allows you to zoom in on sections of your latest measurement trace for closer study. Here
you also can adjust the torque by changing the torque arrow position.
Set
View>Trace to display the A.lyse menu item.
A.lyse
1 Zoom in
2 Zoom out
3 Adjust position
4 Save trace
5.Parameter
1 Low
2 Medium
3 High
1 Torque (angle)
2 Torque (time)
3 Angle (time)
4 Torque, angle (time)
Basic, Quality Control &
Advanced Analysis
Quality Control &
Advanced Analysis only
Advanced Analysis only