Programming ACTA ACTA 4000 User Guide
32 (136) 2008-12 9836 4171 01
Performing ISO 5393 capability study
1. Ensure that the test joints are set up and that the transducer and tool are connected. To view
tool/Pset in the
Result header, open Conf>Interface>User and set Show Pset to On.
2. Select menu block
Q.prog.
3. Select
ISO 5393 and press ENTER.
4. Select
Standard or Custom and press ENTER.
If
Standard, enter a tool name and press ENTER.
If
Custom, select tool, select number of tightening operations and (if applicable) measure
strategy in the dialog boxes that appear.
5. Type tool name and press
ENTER.
6. A dialog box with the following text appears:
(The number of tightenings can be other than 25 according to
Custom programming)
Make 25 tightening each on:
* Hi torque soft joint, Pset HiSo
* Hi torque hard joint, Pset HiHa
* Low torque soft joint, Pset LoSo
* Low torque hard joint, Pset LoHa
Then, evaluate statistics and print report
Press ENTER to Continue
7. Make the required tightening operations. The routing function selects new Pset when required.
To select tool and Pset manually, open Datab>Select tool and select the combination of tool
and Pset. Press ENTER to confirm.
The result is displayed in the
Measurement dialog box after each tightening.
8. Save and print the result.
Evaluate, and if applicable, calibrate the tool. See section Calibrating tools and equipment.

Table of Contents