- 37 -
4.3.4.4 Advanced menu
Equalisation
Starts equalisation. See Multi or Quattro documenta-
tion for details.
Redetect system
Redetects the type of inverter/charger and its features
& configuration. Use this feature when, for example,
a VE.Bus BMS used to be part of a system, and is no
longer.
System reset
Restarts the inverter/charger when it has stopped
retrying. For example after a (very) heavy overload;
or three overloads in a row.
ESS Relay test
Shows the status of the ESS Relay test. Only relevant
when its an ESS system.
4.4 Setting the CCGX controller
4.4.1 Customize the logo on the Boat
& Motorhome page
It is possible to use a custom logo onto the Boat &
Motorhome page.
Type the following address into the web browser of a
device connected to the same network. Using this
address as a template: http://[ip-here]/logo.php
(inserting your device’s IP address between the
square brackets). The IP address can be found by
going to Settings > Ethernet or Wifi. Once the page is
loaded, choose an image file from your device. Re-
boot the CCGX.
4.4.2 Enabling the start/stop function
1. Go to Settings and tap Relay.
2. Set the Function options to “Generator start/stop”.
4.4.2.1 Generator start/stop
1 Current status of the generator
2 Error description
3 Generator run-time since last start
4 Accumulated running time since the first start
5 When the 'test run' option is enabled this item
shows the time remaining until the next test run
6 Running time history for the last 30 days
7 This is the gateway to all other features