- 64 -
9.2.3 MPPT Solar charger + MC4 PV
connectors
The MPPT (Maximum Power Point Tracking) Solar
charger is necessary to connect to the ESS a PV power
module.
It is necessary for any solar power systems and allow
to extract maximum power from PV modules; it
forces PV module to operate at voltage close to
maximum power point to draw maximum available
power. They are 3 pairs of MC4 connectors included
to connect to the PV module. Each pair limited to
30 Amps.
PV module / solar panels are not included in the scope
of supply.
Notes
9.2.4 Sockets configuration
Please find below the table with the different inlets
and outlets sockets configuration:
Battery voltage 48 V Auto Select
Rated charge
current
85 A
Nominal PV
power, 12 V
1a,b)
1200 W
Nominal PV
power, 24 V
1a,b)
2400 W
Nominal PV
power, 36 V
1a,b)
3600 W
Nominal PV
power, 48 V
1a,b)
4900 W
Max. PV short
circuit current
2)
70 A (max 30 A per MC4 conn.)
Maximum PV
open circuit
voltage
250 V absolute maximum coldest
conditions
245 V start-up and operating
maximum
Maximum
efficiency
99%
Self-
consumption
Less than 35 mA @ 12 V / 20 mA @
48 V
Charge voltage
'absorption'
Default setting: 14,4 / 28,8 / 43,2 /
57,6 V
(adjustable with: rotary switch,
display, VE.Direct or Bluetooth)
Charge voltage
'float'
Default setting: 13,8 / 27,6 / 41,4 /
55,2 V
(adjustable: rotary switch, display,
VE.Direct or Bluetooth)
Charge voltage
'equalization'
Default setting: 16,2 V / 32,4 V /
48,6 V / 64,8 V (adjustable)
Charge
algorithm
Multi-stage adaptive (eight
preprogrammed algorithms) or user
defined algorithm
Temperature
compensation
-16 mV / -32 mV / -64 mV / °C
Protection Battery reverse polarity (fuse, not
user accessible)
PV reverse polarity / Output short
circuit / Over temperature
Operating
temperature
-30 to +60°C (full rated output up to
40°C)
Humidity 95%, non-condensing
Maximum
altitude
5000 m (full rated output up to
2000 m)
1a) If more PV power is connected, the con-
troller will limit input power.
1b) The PV voltage must exceed Vbat + 5 V
for the controller to start. Thereafter the
minimum PV voltage is Vbat + 1 V.
2) A PV array with a higher short circuit
current may damage the controller.