EasyManua.ls Logo

AudioCodes Mediant 800 - Connecting to ISDN PRI (E1;T1) Trunks; Figure 6-21: RJ-48 C Connector Pinouts for E1;T1; Figure 6-22: Cabling E1;T1 Ports

AudioCodes Mediant 800
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware Installation Manual 50 Document #: LTRT-10229
Mediant 800 MSBR
6.7 Connecting to ISDN PRI (E1/T1) Trunks
The procedure below describes how to cable the device's E1/T1 trunk.
Warning:
PRI port cabling must be routed only indoors and must not exit the building.
To protect against electrical shock and fire, use a 26 AWG min wire to connect T1 or
E1 ports to the PSTN.
To comply with EMC rules and regulations, use shielded twisted pair (STP) cables for
E1 interfaces on the Mediant 800B model.
Cable specification:
Cable: 26 AWG min. wire
Connector: RJ-48c
Connector Pinouts:
Figure 6-21: RJ-48c Connector Pinouts for E1/T1
To connect the E1/T1 trunk interface:
1. Connect the E1/T1 trunk cable to the device’s E1/T1 port.
2. Connect the other end of the trunk cable to your PBX/PSTN switch.
Figure 6-22: Cabling E1/T1 Ports