6 System Screen
96 © Copyright Reserved Autonics Co., Ltd.
No.
Function and operation
Every Month: Designate day, hour, minute, second to start logging.
Touch to-be set time type and it moves to the relevant setting screen.
Displays time and day of repeat period by the set type.
Designate the repeat number of times to save after starting logging.
Default is 0, if this is set as 0, repeat count is infinite.
If the device is satisfied with the set condition, it saves logging device (save device) to
the file.
Select the device type (word or bit) and touch Device Setand it moves to the device
menu.
Displays the set channel, address, device of the save device.
If it is word device, it displays the set data type (Signed Word: decimal with sign,
Unsigned Word: decimal without sign) of the device.
Displays the number of device to be read continuously from the start address of set
save device.
(Default is 1. In case of bit device, it is available to set up to 8. In case of word device,
it is available to set up to 4.)
Displays the number of logger setting screen.
Saves the set of logger data.