EasyManuals Logo

Avery Weigh-Tronix evolution Series User Manual

Avery Weigh-Tronix evolution Series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #56 background imageLoading...
Page #56 background image
56 Model E1070 Indicator User Instructions
Indicator Operations
Auto Batching by Weight Following is an example of batching for a recipe set as follows:
Batch type: Constant
Batch mode: Automatic
Basis: Weight
1. With the indicator powered up and the scale empty, zero the scale by
pressing the ZERO key…
0 is displayed.
2. Press the F1 key…
The OP1 annunciator lights and output 1 is activated.
Each ingredient may have a built in
delay time between deactivation of
one ingredient and activation of the
next.
3. Add weight to the scale…
When the weight reaches the setpoint for ingredient 1, OP1
annunciator light goes out, OP2 annunciator lights and output 2
activates. See note at left.
4. Add weight to the scale…
When the weight reaches the setpoint for ingredient 2, OP2
annunciator light goes out, OP3 annunciator lights and output 3
activates. See note at left.
5. Add weight to the scale…
When the weight reaches the setpoint for ingredient 3, OP3
annunciator light goes out and output 3 deactivates.
6. Empty the scale and repeat steps 1-5 for the next batch.
Manual Batching by
Percentage
Following is an example of batching for a recipe set as follows:
Batch type: Percentage
Batch mode: Manual
Basis: Weight
1. With the indicator powered up and the scale empty, zero the scale by
pressing the ZERO key…
0 is displayed.
2. Press the F1 key…
The size of the last batch is displayed.
3a). Press the ENTER key to accept the batch size
OR
3b). Key in a new batch size and press the ENTER key…
The OP1 annunciator lights and output 1 is activated.
4. Add weight to the scale…
When the weight reaches the percentage of the batch size set in
the recipe for ingredient 1, OP1 annunciator light goes out.
5. Press the F1 key…
OP2 annunciator lights and output 2 activates.
6. Add weight to the scale…
When the weight reaches the percentage of the batch size set in
the recipe for ingredient 2, OP2 annunciator light goes out.

Other manuals for Avery Weigh-Tronix evolution Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Avery Weigh-Tronix evolution Series and is the answer not in the manual?

Avery Weigh-Tronix evolution Series Specifications

General IconGeneral
BrandAvery Weigh-Tronix
Modelevolution Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals