56
Model E1070 Indicator Service Manual
Follow these steps to access and configure the options:
1. Access the Service menu. . .
CAL is displayed.
2. Press the UNITS key repeatedly until. . .
OPTION is displayed.
3. Press the PRINT key. . .
A-OUT is displayed. This is the analog output menu item.
4. Press the PRINT key. . .
ON or OFF is displayed. ON enables analog output. OFF disables
it.
5. Toggle between ON and OFF by using the TARE or UNITS key and
press the ENTER key to accept the displayed choice. . .
If you pick OFF, A-OUT is displayed and you can continue to the
next menu item, CNTR.
If you pick ON, continue to step 6.
6. Press the PRINT key. . .
LO is displayed. Use this to set the weight which is equal to the
lowest analog output.
7. Press the PRINT key. . .
Current value is displayed.
8. Key in a value and press ENTER. . .
LO is displayed.
9. Press the UNITS key. . .
HI is displayed. This is the weight at which the analog output will
be at maximum.
10. Press the PRINT key. . .
Current value is displayed.
11. Key in a value and press ENTER. . .
HI is displayed.
12. Press the UNITS key. . .
BASIS is displayed. Use this to choose if output is based on gross
or net weight.
13. Press the PRINT key. . .
GROSS or NET is displayed.
14. Toggle between the choices by using the TARE or UNITS key. Press
ENTER when your choice is displayed. . .
BASIS is displayed.