EasyManua.ls Logo

Avidsen ORANE-CONNECT - Page 46

Avidsen ORANE-CONNECT
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN47EN 46
3.3.2 - Pre-flashing time
The flashing light is an important safety
component. It starts when a command to set the
gate in motion is received by the electronic card.
The gate is set in motion around one second after a
command is received.
In certain use cases, it is better that the time
between receiving a motion command and the start
of the manoeuvre is longer. It is possible to increase
this time to 3 seconds.
To set the pre-flashing time, follow the
procedure below
Press PROG for 3 seconds. L0 will flash once
and L1 will switch on.
• Press “PROG” for 3 seconds. L0 will flash twice.
Press PROG for 3 seconds. L0 will flash 3 times.
Press “+” once. L2 will turn on instead of L1.
• Press OK.
If L1 is off, the time is 1 second. Press “+” to
increase it to 3 seconds, then OK to confirm. All
LEDs will turn on and off to confirm the operation.
If L1 is on, the time is 3 seconds. Press “” to
reduce it to 1 second, then OK to confirm. All
LEDs will turn on and off to confirm the operation.
D - BEGINNING OPERATION

Table of Contents