EasyManuals Logo
Home>Badger Meter>Measuring Instruments>ModMAG M2000

Badger Meter ModMAG M2000 User Manual

Badger Meter ModMAG M2000
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
Programming Page 16/51
MID_M2000_BA_02_1807
Low Flow Cut-off
Low Flow Cut-off defines the threshold at which flow measurement will
be forced to zero. The cutoff value can be from 0 % to 9.9 % of the full
scale flow. Increasing the threshold
will help prevent false reading
during “no flow” conditions possible caused by vibrations or liquid
fluctuations.

Other manuals for Badger Meter ModMAG M2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Badger Meter ModMAG M2000 and is the answer not in the manual?

Badger Meter ModMAG M2000 Specifications

General IconGeneral
BrandBadger Meter
ModelModMAG M2000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals