Programming Page 16/51
MID_M2000_BA_02_1807
Low Flow Cut-off
Low Flow Cut-off defines the threshold at which flow measurement will
be forced to zero. The cutoff value can be from 0 % to 9.9 % of the full
scale flow. Increasing the threshold
will help prevent false reading
during “no flow” conditions possible caused by vibrations or liquid
fluctuations.

Other manuals for Badger Meter ModMAG M2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Badger Meter ModMAG M2000 and is the answer not in the manual?

Badger Meter ModMAG M2000 Specifications

General IconGeneral
Flow Measurement TechnologyElectromagnetic
Enclosure RatingNEMA 4X (IP66)
Repeatability±0.1% of rate
Output4-20 mA, pulse, frequency
DisplayLCD with backlight
Power Supply100 to 240 VAC or 24 VDC
Communication ProtocolsHART, Modbus
Process ConnectionFlanged, Threaded
Electrode Material316 Stainless Steel, Hastelloy, Tantalum
Liner MaterialPTFE, PFA, Polyurethane
Accuracy±0.2% of rate
Temperature Range-40°...160°F (-40°...71°C)
Fluid Temperature-4°...302°F (-20°...150°C)
MaterialsStainless Steel, Carbon Steel