5.2.2 Measurement
Totalizer Unit
This parameter establishes the units of measure for the totalizers:
Unit
Unit
L
Liters
UKG
Imperial Gallons
HL
HectoLiter
MIG
Mega Imp. Gal.
Cubic Meters
Lb
Pounds
CFt
Cubic Feet
Oz
Fluid Ounces
USG
U.S. Gallons
Aft
Acre Feet
MG
MegaGallons
BBL
Barrel

Other manuals for Badger Meter ModMAG M2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Badger Meter ModMAG M2000 and is the answer not in the manual?

Badger Meter ModMAG M2000 Specifications

General IconGeneral
Flow Measurement TechnologyElectromagnetic
Enclosure RatingNEMA 4X (IP66)
Repeatability±0.1% of rate
Output4-20 mA, pulse, frequency
DisplayLCD with backlight
Power Supply100 to 240 VAC or 24 VDC
Communication ProtocolsHART, Modbus
Process ConnectionFlanged, Threaded
Electrode Material316 Stainless Steel, Hastelloy, Tantalum
Liner MaterialPTFE, PFA, Polyurethane
Accuracy±0.2% of rate
Temperature Range-40°...160°F (-40°...71°C)
Fluid Temperature-4°...302°F (-20°...150°C)
MaterialsStainless Steel, Carbon Steel