15. Maintenance
CAUTION: Never install a used HEPA lter. Always install a new HEPA lter.
15.2 Replacement of the dust lter on the bottom side
Necessary parts
New HEPA dust lter for the bottom side (R9854480).
2.5 mm Allen key.
How to replace the HEPA dust lter on the bottom side of the projector ?
1. Remove the side cover of the projector, see "Removal of the side cover", page 194.
2. Release (not remove) the two wedge lock screws (A) using a 2.5 mm Allen key as illustrated.
A
A
Image 15-2
3. Remove the lter (F) on the bottom side by pulling out the lter holder (H) as illustrated.
F
H
H
Image 15-3
4. Place a new HEPA dust lter in the lter holder.
Caution: Make sure that the airow indicated on the dust lter match with the airow of the fans.
5. Reinstall the lter holder containing the new HEPA lter.
6. Fasten the two wedge lock screws (A) using a 2.5 mm Allen key as illustrated.
182
R59770179 FLM R22+ 15/03/2010