21. Troubleshooting
Error
code
Description Error Warning
Caused by
Action
2802
LPS start failed
Yes
-
LPS (address 0x28) Replace LPS
2203
BOOST start
failed
Yes
-
LPS (address 0x20) Replace LPS
2503
BOOST start
failed
Yes
-
LPS (address 0x22) Replace LPS
2803 BOOST start
failed
Yes
-
LPS (address 0x28) Replace LPS
2206 Lamp ignition
failed
Yes
-
hot restrike,
lamp with many strikes, maximum
run time exceeded
Let cool down the lamp for at least 3
minutes. Replace the lamp or SPG
with a new one If problem persists,
call a qualied service engineer
2506 Lamp ignition
failed
Yes
-
hot restrike,
lamp with many strikes, maximum
run time exceeded
Let cool down the lamp for at least 3
minutes. Replace the lamp or SPG
with a new one If problem persists,
call a qualied service engineer
2806 Lamp ignition
failed
Yes
-
hot restrike,
lamp with many strikes, maximum
run time exceeded
Let cool down the lamp for at least 3
minutes. Replace the lamp or SPG
with a new one If problem persists,
call a qualied service engineer
2207 Lamp voltage
range
Yes
-
lamp voltage too high or too low Replace lamp
2507 Lamp voltage
range
Yes
-
lamp voltage too high or too low Replace lamp
2807 Lamp voltage
range
Yes
-
lamp voltage too high or too low Replace lamp
2208 Lamp power
range
Yes
-
lamp voltage too high or too low Replace lamp
2508 Lamp power
range
Yes
-
lamp voltage too high or too low Replace lamp
2808 Lamp power
range
Yes
-
lamp voltage too high or too low Replace lamp
4000 Incompatible
hardware
Yes No Incompatible hardware used
Change to correct hardware
4199
FIB reset failed
Yes
-
no communication with FIB
Call a qualied service engineer
5098
Flash full
Yes
-
Internal Backup device has reached
its maximum capacity
Call a qualied service engineer
5097 Flash
management
full
Yes
-
Internal Backup device has reached
its maximum capacity
Call a qualied service engineer
5096
Storing
unsuccessful
Yes
-
Storing the custom settings into
internal backup device has failed
If problem persists, call a qualied
service engineer
5095 Restoring
unsuccessful
Yes
-
Restoring the custom settings from
internal backup device has failed
If problem persists, call a qualied
service engineer
6099
6098
7698 Light pipe temp
high
Yes Yes High temperature on light pipe entry
If problem persists, call a qualied
service engineer
7697 Light pipe temp
open
Yes Yes Temperature sensor on light pipe
not connected
Call a qualied service engineer
7696 Light pipe temp
short
Yes Yes Temperature sensor on light pipe
shorted
Call a qualied service engineer
7695
Red front DMD
temp low
No Yes Low temperature on red DMD
Switching on the lamp will heat up
the DMD
214 R59770179 FLM R22+ 15/03/2010