5. ICMP
5.13 ICMP reset
This procedure requires that ICMP version 1.2.4 or later is installed.
ICMP reset possibilities
• The Star button on the local keypad ( Not for C - and B-series)
• The ICMP reset button in t he GUI of the Communic ator.
• The ICMP reset button in the GUI of the Commander.
• The ICMP reset button in the GUI of the Web Com mander.
• The ICMP hardware reset button located on the front pane l of the ICMP (N ot r ecom mended, use only when all other re
set
possibilities are exhausted!)
How to reset the ICMP?
1. Click on the ICMP reset b utton in the GUI of the Web Commander
Or,
Click on the ICMP reset button in the GUI of the Commander
Note: It can be that the Com ma nder or WEB-C omm ander is not able to send the reset com mand.
Or,
click on the ICMP reset button in the GU I of the C ommunicator (recommended)
Or,
press the Star button on the local keypad for a few seconds (Not for C- and B-series)
As a result the projector is safely prepared for the ICM P reboot. All ongoing events on the ICMP (e.g. ingest) are requested to
end. After a few seconds the ICM P is requested to restart. The RE ADY LED on the front panel of the ICMP starts to blink orange.
In case the I CM P is installed in DP4K-L s eries projector the lasers are switched off and the projector remains in the sam e mode
(e.g. Conditioned). The Star button on the local keypad s tarts blinking green. After the reset of the ICMP the lasers ar e switched
on again.
Once the READY LED lit continuous green the ICMP is up and running.
2. Did the re set of the ICMP fail?
If yes, perform a hardware reset as follows:
a) switch off the lasers of the p rojector or switch of the projector lamp.
b) press the ICMP hardware rese t button a few s econds (reference 3 image 5-13) .
Warning: Resetting the ICMP with the hardware reset button may cause damage to the content on the HDDs. A re-configu-
ration of the whole system may be required!
As a result the projector is s afely prepared for the ICM P reboot. All ongoing events on the ICM P (e.g. ingest) are stopped
immediately and the ICMP res tarts.
3
Image 5-13
WARNING: Resetting the ICMP with the hardware reset button m ay cause dama ge to the c ontent on the HDDs.
A re-config uration of the whole system may b e requ
ired!
R5906787 THOR 26/01/2018 51