Parameter
Parameter manual b maXX
®
1000
Document no. 5.07004.03
141
of 208
4
P2062
Display of the current set value [A].
P2063
Display the signal of the AVI analog input terminal [increment].
1023 Inc
⇔ 10.0 V
0 - 1023 Inc
⇔ 0.0 - 10.0 V
P2064
Display the signal of the ACI or AVI2 analog input terminal [mA or V].
1023 Inc
⇔ 20.0 mA or 10.0 V
0 - 1023 Inc
⇔ 0.0 - 20.0 mA or 0.0 - 10.0 V
P2065
Display the signal of the ACI2 or AVI3 analog input terminal [mA or V].
4095 Inc
⇔ 20.0 mA or 10.0 V
0 - 4095 Inc
⇔ 0.0 - 20.0 mA or 0.0 - 10.0 V
P2066
Display the signal of the ACI3 or AVI4 analog input terminal [mA or V].
4095 Inc
⇔ 20.0 mA or 10.0 V
0 - 4095 Inc
⇔ 0.0 - 20.0 mA or 0.0 - 10.0 V
P2062
Anzeige Stromsollwert 0.0 to 99.9
- Display the current set value 0
A BM_u_DisplayCurrentSetValue 1:1 -
P2063
Anzeige AVI analoges Eingangssignal 0 to 1023
- Display of AVI analog input terminal 0
A BM_u_DisplayAVI 1:1 -
P2064
Anzeige ACI oder AVI2 analoger Eingang 0 to 1023
- Display of ACI or AVI2 analog input terminal 0
A BM_u_DisplayACIAVI2 1:1 -
P2065
Anzeige ACI2 oder AVI3 analoger Eingang 0 to 4095
- Display of ACI2 or AVI3 analog input terminal 0
A BM_u_DisplayACI2AVI3 1:1 -
P2066
Anzeige ACI3 oder AVI4 analoger Eingang 0 to 4095
- Display of ACI3 or AVI4 analog input terminal 0
A BM_u_DisplayACI3AVI4 1:1 -