Parameter
Parameter manual b maXX
®
1000
Document no. 5.07004.03
93
of 208
4
P1122
These parameter is used to set control of mechanical brake via the output terminals, see
ZP1121– for details.
P1123
For standard b maXX
®
1000 (without extension card), the multi-function output terminals
are falling-edge triggered and ZP1123– will display 3 (bit 0 = 1, bit 1 = 1) for no action.
Figure 41: Display the status of multi function output terminals 1
For Example:
If ZP1123– displays 2, it means Relay 1 is active.
The display value 2 =bit 1 x 2
1
When extension card is installed, the number of the multi-function output terminals will in-
crease according to the extension card. The maximum number of the multi-function out-
put terminals is shown as follows.
Figure 42: Display the status of multi function output terminals 2
P1122
Frequenz Bremse einrasten 0.00 to 20.00 Hz
EE Brake engage frequency 0.00 Hz
STOP BM_u_BrakeEngageFrequency 100:1
P1123
Statusanzeige Multi-Funktions-Ausgänge 0 to 255
- Display the status of multi function output ter-
minals
0
A BM_u_StatusMultiFunctionOutputs 1:1 -