Parameter
Parameter manual b maXX
®
1000
Document no. 5.07004.03
61
of 208
4
P0869
This parameter sets the over time detection of the communication card.
P0870
If the b maXX
®
1000 is controlled by CANopen communication, the communication ad-
dress for this drive must be set via this parameter. The communication address for each
b maXX
®
1000 must be different and unique.
b maXX
®
1000 CANopen address is set by parameter ZP0870– only if CANopen hard-
ware address is set to 0 (switch 1 = off, switch 2 = off, switch 3 = off). Otherwise the hard-
ware setting is valid.
Figure 16: DIP switch CANopen address
P0869
USB Kommunikationskarte Zeitfehler 0.0 to 120.0 s
EE USB Communication card over time detection 0.0 s
ON BM_u_USBCommCardOverTimeDetect 10:1 -
Value Meaning
0.0 Disable
0.1 to 120.0 s Over time detection enabled
P0870
CANopen Adresse 1 to 127
EE CANopen address 1
STOP BM_u_CANopenAddress 1:1 -
Value Meaning
0 Disable CANopen
1 to 127 CANopen communication address