4.3
P0866
This parameter is used to set the transmission speed between the communication card
and b maXX
®
1000.
P0867
This parameter defines the communication card protocol.
P0868
This parameter is set to how to react if transmission errors occur.
P0866
USB Kommunikationskarte Übertragungsgeschwin-
digkeit
0 to 4
EE USB Communication card transmission speed 3
STOP BM_u_USBCommCardTransSpeed 1:1 -
Value Meaning
0 Baud rate 4800 bps (bits / second)
1 Baud rate 9600 bps
2 Baud rate 19200 bps
3 Baud rate 38400 bps
4 Baud rate 57600 bps
P0867
USB Kommunikationskarte Protokoll 0 to 5
EE USB Communication card protocol 3
STOP BM_u_USBCommCardProtocol 1:1 -
Value Meaning
0 7, N, 2 (Modbus, ASCII)
1 7, E, 1 (Modbus, ASCII)
2 7, O, 1 (Modbus, ASCII)
3 8, N, 2 (Modbus, RTU)
4 8, E, 1 (Modbus, RTU)
5 8, O, 1 (Modbus, RTU)
P0868
USB Kommunikationskarte Übertragungsfehler 0 to 3
EE USB Communication card transmission fault
treatment
0
ON BM_u_USBCommCardTransFaultTreat 1:1 -
Value Meaning
0 Warn and keep operating
1 Warn and RAMP to stop
2 Warn and COAST to stop
3 No warning and keep operating